This record contains private information, which has been redacted from public viewing.
Record #: O2021-3114   
Type: Ordinance Status: Passed
Intro date: 7/21/2021 Current Controlling Legislative Body: Committee on Zoning, Landmarks and Building Standards
Final action: 9/14/2021
Title: Zoning Reclassification Map No. 2-G at 1218 W Lexington St - App No. 20789T1
Sponsors: Misc. Transmittal
Topic: ZONING RECLASSIFICATIONS - Map No. 2-G
Attachments: 1. O2021-3114 (V1).pdf, 2. O2021-3114.pdf

ORDINANCE

BK IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO:

 

 

SECTION 1. Tille 17 of the Municipal Code of Chicago, the Chicago Zoning Ordinance, is hereby amended by changing the RT-4 Residential Two-Flat, Townhouse and Multi-Unit District symbols and indications as shown on Map No. 2-G in the area bounded by

The alley next north of and parallel to West Lexington Street; the alley next east of and parallel to South Lytle Street; West Lexington Street; a line 150 feet east of and parallel to South Lytle Street; a line 95 feet north of and parallel to West Lexington Street; and a line 154 feet east of and parallel to South Lytle Street

 

to those of a B2-3 Neighborhood Mixed-Use District,

 

 

SECTION 2. This ordinance shall be in force and effect from and after its passage and due publication.

 

1218 West Lexington Street

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Common Address of Property:

 

PROJECT NARRATIVE AND PLANS TYPE 1 ZONING AMENDMENT 1218 West Lexington Street

 

 

 

 

 

RT-4 Residential Two-Flat, Townhouse and Multi-Unit District to a B2-3 Neighborhood Mixed-Use District.

The purpose of the rezoning is to adaptively reuse a 3-story convent. The Applicant proposes to add 14 dwelling units in the existing building. No changes are proposed to the existing structure of the building, which will remain the same size. The existing height of the building at 45'4" will remain. The property is a transit served location and is within 1,320 feet ofthe Racine CTA Blue Line. No parking will be provided.

 

 

PROPOSED

Lot Area

8,089 SF

Density - MLA

577.78

Off Street Parking

0*

Rear Setback

17 feet (existing)

Side (West) Setback

3 feet (existing)

Side (East) Setback

9 inches (existing)

Front Setback

17 feet (existing)

FAR

1.54 (existing)

Building Height

45 feet 4 inches (existing)

 

 

Transit Served Location seeking parking exemption

 

m km sui ruuiicauon

 

 

 

55.00' PL

UNIT fil 1,035 SF 3 Bed/2Bath

4.00' PL r

UNIT #2 395 SF 1 Bed/1 Bath

UNIT #3 475 SF 1 Bed/1 Bath

UNIT #4 475 SF 1 Bed/1 Bath

UNIT #5 395 SF 1 Bed/1 Bath j

UNIT m 1,035 SF 3 Bed/2Balh

 

Proposed Firs! Floor Plan

\0)

M.23.202

f.rtrJl-f.;.' in u-ti

 

 

 

1218 W. Lexington St.

, IL C0GO7

 

HECfiOOUJ

 

irmcnocm

UNIT #1 1,055 SF 3 Bed/2Bath

 

io-io-xttr-0*

 

IttlMOCVi i

if iwir-i&-

 

1' j etorjxyi jniCHiN ; 1 5 wwxu-r

 

 

 

UNIT 1/2 680 SF 2 Bed/1 Ball)

BEWKXUI

 

KOfiOCUl

17-rm*

 

UNIT #3 680 SF 2 Bed/1 Bath

 

?

 

-IUKM1Y KOUKD

 

etirooui

 

IMHU-W

3"

 

UNIT #4 1,055 SF 3 Bed/2Bath

 

uvwanoou iw<ir-4T

M'-TXIC-C

 

1218 W. Lexington St.

Chicago, IL 60607

 

 

 

 

 

 

 

 

 

 

 

 

Proposed Second & Third Flaof Plan 3/32'=1'-0' 04.23.2021

 

T/STAIR PARAPET +48'-0"

B/STAIR ROOF

ROOF

 

T/PARAPET

 

3APJJW> +38'-5*~

 

B/NORTH ROOF

+37'-3" v B/SOUTH ROOF

+33'-2'

 

mm

R

T/THIRD FLOOR

 

 

FLOOR ^-n +24'-8"CT

 

m

Existing South Elevation

T/SECOND FLOOR +12'-10"

 

 

T/FIRST FLOOR tV-0" GRADE

O'-O"

 

T/STAIR PARAPET +48'-0"

 

Proposed South Elavalion

ENTRY DOOn AND WINDOW TO DC flEPlACED FOR UNIT«

 

1218 W, Lexington St.

Chicago, IL 60607

1/8"=1'-0-

 

Existing and Proposed South Elovalidns

04.23.2021