metroPCS Authorized Dealer Acct. No. 392605 - 4 Permit No. 1120555


Be It Ordained by the City Council of the City of Chicago:

SECTION 1. Permission and authority are hereby given and granted to metroPCS Authorized Dealer, upon the terms and subject to the conditions of this ordinance to maintain and use two (2) sign(s) projecting over the public right-of-way attached to its premises known as 3409 W. Belmont Ave

Said sign structure(s) measures as follows; along W Belmont Ave:
One (1) at thirteen point zero eight (13.08) feet in length, three point two five (3.25) feet in height and ten (10) feet above grade level.
One (1) at six (6) feet in length, four (4) feet in height and fourteen (14) feet above grade level.
The location of said privilege shall be as shown on prints kept on file with the Department of Business Affairs and Consumer Protection and the Office of the City Clerk.

Said privilege shall be constructed in accordance with plans and specifications approved by the Department of Transportation (Division of Project Development) and Zoning Department - Signs.
This grant of privilege in the public way shall be subject to the provisions of Section 10-28-015 and all other required provisions of the Municipal Code of Chicago.
The grantee shall pay to the City of Chicago as compensation for the privilege #1120555 herein granted the sum of four hundred ($400.00) per annum in advance.

A 25% penalty will be added for payments received after due date.

The permit holder agrees to hold the City of Chicago harmless for any damage, relocation or replacement costs associated with damage, relocation or removal of private property caused by the City performing work in the public way.
Carlos Ramirez-Rosa 35xn Ward
Page 1

Authority herein given and granted for a period of five (5) years from and after Date of Passage.


(Page 4 of 6)

Authorized Dealer
COLOR SCHEDULE
| | White Substrate (Material May Vary) Alton #2500-3412 Purple Vinyl







DOUBLE SIDED LIGHT BOX
FACE TO BE #2447 FLAT WHITE ACRYLIC, W VINYL GRAPHICS ON FIRST SURFACE. BACKGROUND TO BE ARLON #2500-3412 PURPLE VINYL

SIGN IS INTERNALLY ILLUMINATED W H.O. FLUORESCENT LAMPS.
^ signs
773-267-6007 | solc^tf^ignb.com

Client: MetroPCS Landlord: Start Date: 00/00/0000 Last Revision: 00/00/0000 Job* 00000 Drawing*: OOOOOa.vl s1 / e1 Page: 1 of 2 Sales Rep: Seung Park Designer: Vemon James
Address: 3409 W. Belmont Ave. Address:
Chicaqo, IL Client Approval
Tel: Tel:
Email: Email: E322358§|
Landlord Approval
C0PYRIGHT2IMJ,SYTFASijiu THB RENDERINGS THE PROPStTY OF 1TA SIGNS, INC AN1) THE MRTtVH^ ff BAJf UNPUBUSHEDC4UGNALDRA1MNGN£TTO&
(Page 2 of 6)


Front-Lit Channel Letters w/ LED illumination • Raceway Mounted

as so. rr. total
43 SO. FT. TOTAL (ENVELOPE METHOD)
iEiec!rical-Detni!:-GhnnnelLetters--
White Trimcaps / Black returns
Mean wellCLG-60-12
(1) 60w Transformers @ 0.80
Total Amps: 0.80 (1) Minimum of 20 amp 120V Circuit Req.
Specificatioii5:-L£D-Channe! Letters
1. Easting Facade Concrete Block/ Brick
2.0.040* Aluminum letter returns pamted to match Black
3.0.125" x 1' Black Jewehto trimcap
Vi" Drain holes at bortom\ of letter cans (2) per letter
[General Motes:
.040 White Aluminum backing
Section _ LED Channel Letter Raceway mount installation Scale: N.T.S.
This sign is to be installed m accordance with the requirements of Article 600 of the National Electrical Code
Grounded and bonded per NEC 600.7/NEC 250
Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps
Sign Is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
'For multiple signs, a disconnect is permitted but
not required for each section
(interior of sign can will be white for rraxrrrrum illumination)
Irrterone UL approved red LED's
UL approved flexible conduit connectors 7.1/8'Red Aoyhte #2283
LISTED
8. UL approved LEO transformer (Mean well)
X . ELECTRICAL NOTES /
^* Sign Conoanv DOES MOT provide primary electrical lo sign ^
Fewer io the sign musi be oons bj' a licensed eiecirical contractor o' licensed electrician. Each sign must have: 1. A minimun ol one dedicated 120V 20A circuit
Junction box installea-uilhin 6 ieei ol sign
Three wires: Line, Ground, Neuirai
9. UL approved waterproof disconnect switch per NEC 600-6
10. Aluminum Raceway to match fascia color
11.1/4' x 2* x 11' Aluminum Bracket
UL approved Liquid tight metallic conduit
5:500 !\! Kari'ir: Aw; Cn^^tjO.'lL C 773-267-6007 | salesSttasinjis
(All penetration will be caulked w/ high grade silicone)
Mounting hardware to suit (Non-Corrosive)

Client: Metro PCS Landlord: Start Date: 00/00/0000 Last Revision: 00/00/0000 Job*: 00000 Drawing*: 00000a v1 s1 / e1 Paga: 1 of 2 Sales Rep: Seung Park Designer.
Address: 3409 W. Belmont Ave. Address:
Chicago, IL Client Approval
Tel: Tel:
Email: Email: £322358^
Landlord Approval
COPVnGHT2)11,BYTFASiins THIS RENDERING IS THE PROPERTY Of TFA SIGKS. WC AND THE PARTY WHICH REQUESTED THE RENDERING IT IS AN UNPUBLISHED ORIGINAL DRAWING NOT TO BE REPRODUCED OR EXHIBITED WITHOUT THE CONSENT OF TEA SIGNS. INC