City Council
Meeting Date: 01'0^-l°>i
Committee on Buildings
(signs)
ORDERED, That the Conirmssioner of Buildings is hereby directed to issue a sign permit to: (Contractor's name and address) KGD Enterprises, Inc (dba) Chicago Sign, 26w 535 Saint Charles Road, Carol Stream, IL 60188_
for the erection of a sign/signboard over 24 feet in height and / or over 100 square feet (in area of one face) at: TJ Maxx, 3562 E. 118th Street.
Such sign(s) shall comply with all applicable provisions of TITLE 17 of the Chicago Zoning Ordinance and all other applicable provisions of the Municipal Code of the City of Chicago governing the construction and the maintenance of outdoor signs, signboards and structures.
Dimensions: Length 30 foot 6 inches
Height 7 foot
Height above grade/ roof to top of sign 16 foot
TOTAL SQUARE FOOT AREA 214 Square feet
ZONING SIGN PERMIT APPLICATION DEPARTMENT OF ZONING CITY OF CHICAGO OFFICE OF THE ZONING ADMINISTRATOR
Application For KGp Enterprises, Inc (dba) CHICRGnfIGN John Doyle_
(Name of Sign Company)
Location - Street Address: 3562 E. 118th Street_TJ MAXX
Zoning District: PD 248
Cl-3
4D>6«
RS-2"
,_|<
PD 248
t
Sign
-Z/-t=!
NORTH
2. 3. 4.
5. 6.
8. 9.
Type of Sign (check one for each section)
a. ) □ Signboard, Kl Flat, □ Projecting, or □ Awning
b. ) [& Business ID. or □ Advertising
□ Non-illuminated, Kl Illuminated, □ Flashing, and/or □ Moving
Height above curb level 16 ft,_ in.
Gross Area of sign 214 sq. ft.
Total area of all signs on the lot 214 sq. ftThis Store
Project over public way; yes or(no) If yes_ft,_in.
Distance from curb line 1800 in.
Distance from expressway or major route (within 1000 ft.) dna ft.
Is sign visible from expressway or major routes yes or (n<j (circle one) Distance from park (over 10 Acres) dna ft. Distance from residential zone dna ft.
ALL OF THE ArWOV
SIGNATURE NOTE:
ESTIONS MUST BE ANSWERED FULLY
IN B6-6/andB6-7dWstricts, exact sign copy must be indicated For roof signs, indicate height above grade_ft.
REVISED 8/91
28"$ t
EXISTING FRONT ELEVATION
CODE ALLOWANCE
*** LICENSEO CONTRACTOR APPLIES IN PERSON *** Zoned: PD 411
Wall Sign: Box Entire Word - PD Zoning can only have tenant identification signs - sq ft allowance is 4 x's the front of bldg or 800 total sq ft for all signs - can have more than 1 sign - just do not go over sq ft allowance - no min letter size
Ground Sign: to change a face panel you do need a permit
Under Canopy Signs: have to go to the city for a public right of way permit
(fl) FRONT ELEVATION
W FABRICATE & INSTALL SET OF
5'-0"H. ILLUMINATED CHANNEL LETTERS
SIGN MUST BE MOUNTED CENTERED HORIZONTALLY* VERTICALLY FASCIA AREA INDICATED ON ELEVATION I PHOTO
PROPOSED FRONT ELEVATION 30'- 61/2"
r-6 3/8"
o
Q
TJMR-60 qWO&gg^ ^ILLmsiGNlLcT3Z.
£BN\C ^SELECT
\J INC
2' X 2" ANGLE MOUNTING CLIPS (MIN. 4 PER LTR REQ'D.) HELD W/ 3/8" GAL. LAG t SHIELDS FOR MTG. TO MASONRY. (SILICONE CAULK SEAL AT WALL PENETRATION) ALL H'WARE CONTINOENT ON ACTUAL WALL CONSTRUCTION
.040M ALUMINUM RETURNS _
PRE FINISHED MATTE BLACK
1" BLACK JEWEUIE TRIM-CAP. (48' LTRS. OR LESS) 2' BLACK JEWELITE TF1MCAP (OVER 4B" LTRS.j
3/16" THK. RED PLEXI FACE #2793 S.G.
RED LED STRIPS (5 PER FT.) 4 Vi ON CENTER. NO LESS THAN 2 Vi ' FROM RETURNS LED STRIP MTD TO BACK OF LETTER W/VHB TAPE
AND MECHANICALLY FASTENED W/ RIVETS AT START i END OF EACH STRIP 4 EVERY 19" LENGTH
Vi" SEALTITE AS REQ'D -
ELEC. CUT OFF SWITCH ON RETURN POWER PACK AS REQUIRED (US LED) CAULK @ WALL PENETRATIONS J-BOXBY ELECTRICIAN .0B3" ALUMINUM BACK PTD WHITE INTERIOR OF LETTER PTD. WHITE
NOTCHED RETURNS POP-RIVITED TO BACK (CAULK AROUND PERIMETER)
1/4" DU. DRAIN HOLE (MIN. 2 PER LTR)
NOTE: ALL ELECTRICAL PENETRATIONS TO BE ON ONE LINE (HORIZONTALLY)
120 VOLT 20 AMP. PRIMARY ELECTRIC CIRCUITS BROUGHT TO SIGN AREA W/ FINAL CONNECTION BY OTHERS. 10' WHIP-LENGTH REQUIRED
30'- 6 1/2"
V-6 3/8"
TJMR-60
\ M
ACTUAL TOTAL 151.55 sq.ft.
T.J.MAXX LETTER SECTION (RED FACES) MASONRY WALL
NOT TO SCALE
REQUIRED
CIRCUITS REQUIRED |l)-20AMP
(120 VOLT)
3.6 AMPS
SS# 41109R1
~QSLCT
\J INC
<4DD MACK DRIVE CROYDON, PA 19D21 PH: 21 9.7BB.3B9S FAX 7BB.798B
TJMaix
3562 E 118th St/Avet) Lake Point Plaia Chicago, IL 60617
J.Wi By:
CHANNEL LETTERS SECTION
Changes To This Rev.:
MUM. SIGN ELEVATION
SCALE: 1/4"=1'-0"
CODE ALLOWANCE
Cotle Allowance City of Chicago
*** LICENSED CONTRACTOR APPLIES IN PERSON *** Zoned: PD 411
Wall Sign: Box Entire Word - PD Zoning can only have tenant identification signs - sq ft allowance is 4 x's the front of bldg or 800 total sq ft for all signs - can have more than l sign - just do not go over sq ft allowance - no mln letter size
Ground Sign: to change a face panel you do need a permit
Under Canopy Signs: have to go to the city for a public right of way permit
TMs raw .15 L) susirit;*! fcr ye.r vc js*fl a». ir :cr.n«=tl3i ■Mt e p"o,«rt :*rg : an.^i by S?r\ ce Salpd. he I .s rot ra b« 3-?rtr. ia an/ore d-3 da ycjr ctqin za'JcSi, re is it :o m Lass, rep'3d_c«: ;::!« z: e.il:fte:h ar-j fiufi c.
csfriss cr o' 5s"n :e S« Bd, h:
Tj-mcDK
Y OF CHICAGO
DEPARTMENT OF BUILDINGS
Sign Permit Application
APPROVAL NUMBER
APPLICATION NUMBER
100376625
ANNUAL FEE
WORK CODE
DRAWINGS
□
YES
ATTACHED |-j NQ
DATE OF APPLICATION
12/18/2010
ADDRESS OF SIGN
3562 E 118TH ST, 60617-
ORIGINAL PERMIT NUMBER
TYPHIS PERMIT
NEW CONSTRUCTION (SIGN)
PAYER OF ANNUAL INSPECTION
STORE MANAGER. TJ MAXX 3562 EAST 118 TH ST CHICAGO, IL 60617
(000)000-0000
SIGN MANUFAC11IRLR
KGD ENTERPRISES
ADDRESS WHERE SION C AN DE SEEN I'RIOR il l ERECTION
TICKET NUMBER
REINSPECTION CONTROL NUMBER
TYPE ()l: SUITOR 1 FOR S1C1N
BUILDING
SIGN BOARD SUPPOR 1 MEMBERS
OTHER
ANNUAL FEE CONSTRUCTION FEE 1017 B FEE TOTAL FEE AMOUNT PAID BALANCE DUE
|
Check # for Zoning |
200.00 |
|
200.00 |
Cheek ft for DCAP |
|
|
TYPE OP SIGN
FLAT OR BOX
30
IN
6
SQ FT.
214
FT
7
SIGN HEIGH r ABOVE GRADE/ROOF
LBS 300
16
SIlArEOFSIGN IRREGULAR
SIGN WILL READ
TJ MAXX
NO. OF LAMPS
500
TOTAL WATTAGE
120
TYPE OF LAMP OTHER
NO OF BALLASTfTRANSFORMERS
10
CONTRACTOR WILL INSTALL
INPUT OF TRANSFORMERS
120
FEEDERS
CUSTOMER LEADS
TYPE OF SWITCH
SPECIAL
location of swncH LISTED FLUSH TOGGLE
SIGN LOCATION
ILLUMINATED WALL SIGN WITH LOGO AND LETTERS, READfNG TJ MAXX., SOUTH ELEVATION
Tlie undersmned certify that the statements in thisaDDlication are true and correct and that all work done under the proposed permit will conform to the reauirements of the Chicauo Municipal Code
E92687
ELECT CON1R
KGD ENTERPRISES, INC.
ELECTR
ADDRESS
204 N GARY AVE WHEATON. IL 60187
BOND NO 0 ¥%f tlT7'2/2~
N93I20
SIGN ERECTOR
KGD ENTERPRISES
SIGNER
ADDRESS
204 N GARY WHEATON IL, 60187
The perm
is application will authorize only signs here applied for. If other signs are to he erectei
additional permits
City of Chicago
Richard M. Daley, Mayor
Department of Buildings
Richard Monocchio, Commissioner
ES_PERM_APP_WEBCEH0I0808 AP #:100376625 Page 1 of 2
TYPE OF BUSINESS
COMMERCIAL
Other: RETAIL
Name: TJ MAXX
LIC#. _
Renewal Date:
Projects Over:
vate Property ^Public Way
Grant Permit #:
SIGN BOND REQUIRED?
□
YES
COUNCIL ORDER REQUIRED
IxJyes
is special permission required from chief electrical □yes
if yes, attach letter of request
□ Planned Development/Manufacturing PMD/PD#: PD 248 Zonins District: OTHER Other: PD
TIME STAMP
TYPE OF SIGN: | | ADVERTISING
□ BUSINESS
|X| ILLUMINATE | | FLASHING
□
MOVEABLE
TOTAL STREET FRONTAGE OF. LOT (IN FEET)
146
TOTAL AREA OF NEW SIGN (SQ.FT.)
214
TOTAL AREA OF ALL SIGNS ON LOT (SQ.FT.)
214
HEIGHT OF SIGN ABOVE GRADE (TO TOP)
23 ft in
DISTANCE OF CURB LINE OUTER EDGE (fi) DISTANCE OF STRUCTURE INNER EDGE (fl)
342
SIGN CLERK
APPROVED FOR PERMIT
DISTANCE FROM (fl):
A. PUBLIC PARK (OVER 10 ACRES)
B EXPRESSWAY (IF LESS THAN 1.000 FT )
C. RESIDENCE DISTRICT (ADVERTISING SIGNS ONLY)
REMARKS
IF REPLACEMENT SIGN OR CHANGE OF FACE, WHAT DOES THE EXISTING SIGN READ'1
Original Payee:
Landmark Hold: □ Status:
ZONING (OFFICE USE ONLY)
ES PERM APP WEBCEH010808
AP #: 100376625