uiliinqs '
City Council Meeting Date Committee on Buillings
(signs)
ORDERED, That the Commissioner of Buildings is hereby directed to issue a sign permit to: (Contractor's name and address)
£o<rfof*Jrt. VP S^HonS . S5G2? Al. ffefon Aj£
r^cc^o tL Q>Q<jbO
for the erection of a sign / signboard over 24 feet in height and / or over 100 squareJeeTTjh area of one face) at: (Business NAME^8rftBBRE-S^)
Pole. S\?K, 2V-tP" * 7'- l"
£Urofg>, XL CoOT^ I
Dimensions: Length ~7'~\ " Height' 2-^ I O'
Height above grade / roof to top of sign H
TOTAL SQUARE FOOT AREA I 76 f f ^
Such sign(s) shall comply with all applicable provisions of TITLE 17 ofthe Chicago Zoning Ordinance and all other applicable provisions ofthe Municipal Code of the City of Chicago governing the construction and maintenance of outdoor signs, signboards and structures.
Alderman, Sty Ward
CITY OF CHICAGO
DEPARTIVIENT OF BUILDIIXIGS
Sign Permit Application
APPROVAL NUMBER
ANNUAL FEE
WORK CODE
APPLICATION NUMBER 100514514
I | YES
DRAWINGS ATTACHED [j NQ
DATE OF APPLICATION
TYPE OF SIGN
10/23/2013
FLAT OR BOX
24
ADDRESS OF SIGN
. 4345 W BELMONT AVE, 60641 -
FT. 7
IN.
10
ORIGINAL PERMIT NUMBER
SQ.FT.
176
LBS
500
TYPE OF PERMIT
FT
4
SIGN HEIGHT ABOVE GRADE/ROOF
NEW CONSTRUCTION (SIGN)
PAYER OF ANNUAL INSPECTION
MANAGER, STORE 4357 W BELMONT AVE CHICAGO, IL 60641
(773)777-7288
SHAPE OF SIGN IRREGULAR
SIGN WILL READ
CITGO
SIGN MANUFACTURER
FEDERAL HEATH
TOTAL WATTAGE
960
ADDRESS WHERE SIGN CAN DE SEEN PRIOR TO ERECTION
TYPE OF LAMP OTHER
INPUT OF TRANSFORMERS
TICKET NUMBER
REINSPECTION CONTROL NUMBER
NO. OF BALLAST/TRANSFORMERS 2
CONTRACTOR WILL INSTALL
FEEDERS
CUSTOMER LEADS
TYPE OF SUPPORT FOR SIGN CANOPY
TYPE OF SWITCH
KNIFE
SIGN BOARD SUPPORT MEMBERS OTHER
ANNUAL FEE CONSTRUCTION FEE 1017 B FEE TOTAL FEE AMOUNT PAID BALANCE DUE
|
Check # for Zoning |
200.00 |
|
200.00 |
Check tt for DCAP |
|
|
location of switch LISTED FLUSH TOGGLE
SIGN LOCATION
CITGO - POLE SIGN
The iindersiimefl certify that the statements in this annlicatinn are tnie and correct and that all work rtnne under the nrrtnosed nermit will conform fn the reauirements nf the Ohiciurn Municina! Code
E93308
N93077
SIGNER
ELECTR
ELECT CONTR
LITE ZONE ELECTRIC
SIGN ERECTOR
CORP.ID SOLUTIONS INC
ADDRESS
7943 N. KENNETH SKOKIE, IL 60076-
ADDRESS
5563 N ELSTON AVE CHICAGO X IL, 60630
SUPF.RVISOR SIGNATURE
The permit issued on this application will authorize only signs here applied for. If other signs are to be erected they must be covered by additional permits
City of Chicago
Rahm Emanuel, Mayor
Department of Buildings Michael Merchant, Commissioner
Page l of2
AP #:100514514
ES PERM APP WEBRD060211
TYPE OF BUSINESS COM GAS STATION Other: CITGO |
SIGN BOND REQUIRED? f_H YES |
Name: CITGO |
COUNCIL ORDER REQUIRED fx| YES |
|
LIC #: |
is special permission required from chief electrical [x]yes if yes, attach letter of request |
Renewal Date: |
Projects Over: [y"1 Private Property [n1 Public Wav Grant Permit #: |
1 1 Planned Development/Manufacturing PMD/PD#: Zoning District: C1 Other: C1 -1 |
TIME STAMP |
TYPE OF SIGN: r~| ADVERTISING [x] ILLUMINATE fj MOVEABLE [xl BUSINESS I | FLASHING |
TOTAL STREET FRONTAGE OF LOT (IN FEET) 275 |
TOTAL AREA OF NEW SIGN (SQ.FT.) 176 |
TOTAL AREA OF ALL SIGNS ON LOT (SQ.FT.) 948 |
HEIGHT OF SIGN ABOVE GRADE (TO TOP) 28ft 10in |
DISTANCE OF CURB LINE OUTER EDGE (ft) 10 DISTANCE OF STRUCTURE INNER EDGE (ft) 17 |
SIGN CLERK |
APPROVED FOR PERMIT |
DISTANCE FROM (ft): A. PUBLIC PARK (OVER 10 ACRES) 1,000 B. EXPRESSWAY (IF LESS THAN 1.000 FT.) 1,000 C. RESIDENCE DISTRICT (ADVERTISING SIGNS ONLY) 150 |
REMARKS |
IF REPLACEMENT SIGN OR CHANGE OF FACE, WHAT DOES THE EXISTING SIGN READ? Original Payee: |
|
Landmark Hold: I I Status: |
ZONING (OFFICE USE ONLY) |
|
|
|
Page 2 of 2
AP #:100514514
ES_PERM_APP_WEB RD060211
CITY OF CHICAGO
DEPARTMENT OF ZONING AND LAND USE PLANNING
! SIGN SITE PLAN
( ALL IN FORMA TION MUST BE COMPLETED AND LEGIBLE)
Site Address: 4,345 /.V fed! MrfOYV\~ _!_ of S_ applications
Sign Company Rep Name:
Phone(773) 76.3 -?6on EXT
(Below: Building, streets and location of sign on lot or structure) North
West
SIGN USE:
Bus. ID (On-premise)
Business Lice. #
South
TYPE OF SIGN:
Flat Wall , U
Freestanding 0
Advertising (Off-premise) U
Awning D
Marquee □
High Rise Building □
PERMIT TYPE: New Construction Change of Face Previous Permit U
Projecting Private D
Projecting Public Way □
Public Way Use -Permit #
TOTAL SQUARE FOOTAGE:
Square footage of this proposed sign } /1 (n ~n
Gross area of all proposed signs f 07
Area of all existing signs
(not including proposed) on Zoning Lot SuL^^ ^
East
□ □ □
SIGN CHARACTERISTICS: Non- Illuminated D Illuminated 0[ Changing Image Video Display
Flashing
DISTANCE FROM: Curb Line: \Q/
Expressway, Toll Roads or Major Route (n/a if over 1000 ft) WOO Park (over 10 acres) \ OOP Residential Zone / *Z?Q Existing Off-premise on same side of street: AT /A~
Signature : ^^^1^- /^fe^Z^E^
(.Rsvised 4/10)
N
FEDERAL HEATH
SIGN COMPANY
«w Ffidet-aiHeim.com
1500 North Bolton Jacksonville, Texas 75766 |903) 589-2100 Fix [903] 589-2101
Other Office Locations: Los Angeles - Oceanslde - Las Vegas Tacoma - Kansas City - WUIowbrook Milwaukee - Euless - Houston San Antonio-Adanta Tampa - Daytona Beach
Buildincj Cujjltv Sgrugt For American Suiincu
Revisions:
Account Rep: (J . Fuller
Drawn By. a.CfUZ
Project/Locauon:
Job Number:
TTtis original drawing is provided as pari of a planned project and is not to tie exhibited, copied or reproduced without the written permission of Federal Heath Sign Company LLC or Ics authorized agent
CM 32425 E
File Name:
Date: 04.30.10
1 Of 1
Sheet Number: COLORS
L8-3124 PAINT WHITE
L8-6394 PAINT ME0.BED
L8-6839 PAINT LT. RED
L8-676B PAINT DK. RED
L8-6715 PAINT BLUE
L8-7758 PAINT GREEN
ELECTRICAL WIRING INFORMATION
@ Black/ White/ Green 120V 60H2 Ballast Power 1.8 amps (b) Blue/ White/ Green Twisted LED II Power Leads
(c^) Dedicated Receptacle w/ Fuse (d) Lamp Relay Control Box
X
Translucent Copy
LED II Power Supply This Side Only
Single Lamp F72 Tl 2 c/w HD or F96 Tl 2 c/w HD
Light Baffle
Cabinet Fasteners
Wiring RWay
Ballast EESB-424-I3L 1:80 AMPS 120V 60H2
Face Display Retainer Molding
Thermoformed Display Face Panel
Controller Electrical Box
Protective Lens
COLUMN SPECS. Drill & tap (4) S/\b"0 for 3/8"- 16 Holes & (1J 23/3Z0- 14 NPT For Electrical Outlet
REAR FACE PANEL & LED II DISPLAY SLAVE SIDE
Map Output
Address
3159 NKOSTNER AVE
Zoning
I | Business
ISffl Commercial
I | Manufacturing
I [ Residential
| | Planned Development
I | Planned Manufacturing
Downtown Core \ ;,';| Downtown Service I | Downtown Mixed | | Downtown Residential IMM Transportation F~l Parks & Open Space £J Zoning Boundaries
Historic Preservation CHICAGO LANDMARKS \'/r\ Chicago Landmarks Landmark Districts
Chicago Historic Resources Survey - Buildings subject to Demolition-Delay Ordinance □ Red j | Orange
£53 Water ; j Cemetery ' Municipalities
Lakefront
£p Pedeslrian Slreels
\ | Buildings
I I Parcels
Streets
Curbs
j^Zil Forest Preserve
! j City Boundary
(nftnuatcn provided on tbe City of Chcago web sie should not be used as a substitute for legal, accounting, real estate, buskess, tax, or other professional advce. The City of Chcago assumes no liability, for any damages or bss of any kind that might arise trots the use of, misuse of, or the babiSty to use the Ciy web sie and-or the materials conlaixdontbe website. Tbe Ciy ofChcago also assumes no liability for kuproper or nconect use ofnateriab oriiformatba :ontaittd on is web sie. AQ materiab that appear on the Ciy ofChcago web sie are distributed and transmitted as is, without warranties of any khd. either express or inpaed, and subject to the terms and conditions stated h this disclainer.
SUPPLEMENTAL APPLICANT
This Supplemental Application must be completed and submitted along with the Sign Permit Application. All fields must be completed. If a field is not applicable you must answer "n/a" in the field.
CITY: O F- C H I C A G O
DEPARTMENT OF
BUILDINGS
City of Chicago
Sign Permit Application
(THIS IS NOT A PERMIT)
Application Number: IflQ 6J ^f?/ ^ Date of Application: IQt'Ub /l~0\3
Address of property where sign will be erected:. u, fld^ovxf Ave,
Does property have multiple addresses? □ Yes No
If yes, please list all addresses:
Is this building vacant? □ Yes ^ No
If yes, is it registered under the Vacant Building Ordinance? Registration #
Section 1 - Applicant
Applicant is the Owner (of the real property) □ Lessee (of the real property) $
Name of Owner of Real Property:
Address:
Email:
Phone #:
Mobile*:
Name of Lessee of Real Property:
Name:
Phone #: %22- - ^4%- Mobile #:
.Address: £ldr{<Jf£ KaftaAu,, ^faWJlMlHw}
Email: f. Ix^fftt r\\yO, C&w\
Section 2 - Contractors
Payer Company of Annual Inspection Fee:
.Address: Email:
Name of Contact of Payer Company:
. Name of Payer Company:
Phone #: Mobile #:
Electrical Contractor:
Email: ytKoi^vgif \* ft* 7-Vv^eleL\f\\&**
Address: ^ ^WrxiMrs £\ZrKt. t TJ - License*:
Phone#: Mobile #
Website: Ut/Jlj. [ \ Y^TjD^f d.-eXrVjV , C_D\A^\
Sign Erector: (SiCil&fn^ ^ft fy9lvA.flflK\S
Bond #:
Registration #: Al C/3 O? 7
Address: Al. fh\o^\ r^\tC C\a\ Cfrft?# TL &C)£So
Phone #: TlX'l&b'YCCn Mobile #: Email: r^Tfhrt^ri" rJSoiu.A^nS a*,
Website:
P/'cture or rendering must be attached depicting sign placement with before and after view, section 2 continues on next page
City of Chicago Sign Permit Application continued
Expediter:
Address: : License #:
Phone #: Mobile #: Email:
Website:
Section 3 - Sign and Structure Details
(Please check all that apply)
Sign Category:
On-Premise (Business ID): □ Dynamic $ Static
Business License # of Tenant Business: _
CJT GO
Off-Premise (Advertising): □ Dynamic L Temporary: □ Special Event: □
Sign will read (Please provide a description, picture and shop drawing):
Type of sign (Mark all that apply):
- Awning □ Canopy Freestanding □ Marquee □ Projecting □ Dynamic Image Display
- Wall □ Painted □ Cabinet/Frame □ Vinyl □ Projected image □ Flashing
- High Rise Building □ Hotel/Hospitals □ Other buildings:
What is the dimension ofthe wall on which the sign will be installed?.
Where Is sign or sign structure mounted? □ Inside the building Outside the building
Is the sign or sign structure attached to a building or wall?: □ Yes ffi No If yes, which wall of building? N E S W Is this a freestanding sign? ^ Yes □ No Location of sign on lot: 5 ($ Which direction does sign copy face? N^e)S($)
Does any portion of the sign, sign structure or attachments cover, obscure or obstruct an existing window in a residential unit whether occupied or not? □ Yes □ No
Does any portion of the sign, sign structure, or attachments extend on or over the public way? □ Yes No
If yes, what is the public way use permit number?
Sign Panels: Back to back within 30 degrees of parallel □ Yes $ No Number of Faces:
Sign Support Structure: ^Pole □ Roof □ Ground □ Building □ Windows □ Other:
Does any portion of the sign or sign structure extend 24 inches above the roof line as defined in 17-17-02149 ofthe Municipal Code of Chicago? □ Yes ^ No
Picture or rendering must be attached depicting sign placement with before and after view.
> Section 3 continues on next page
f
City of Chicago Sign Permit Application continued
Section 3 continued
o
Inches
Feet
Dimensions of Sign Structure (i.e. cabinet, frame, awning, canopy)
Length: ^ Feet / Inches Height: 7- ^ Feet 1(0 Inches Depth: |_
Area: \]Cr\ So Ft. Weight: f)dO lbs.
Shape of Sign: f \-Q-W^ ,
/
Sign Height above Grade:
Ft.
From Grade to Bottom of sign or sign structure, whichever is lowest: From Grade to Top of sign or sign structure, whichever is highest: 7-Tj -|0" Ft. Is City Council Order required?* j^Yes □ No
*AII signs in excess of 100 Square Feet in area OR in excess of 24 feet above grade require a City Council Order pursuant to Section 13-20-680 ofthe Municipal Code of Chicago
Dimension of Sign Elements pursuant to Section 17-12-0601 of the Chicago Zoning Ordinance:
Length: ^7 Feet 1 Inches Height: inches Area: _ Sq Ft.
Electrical Contractor will install: Feeders: □ Yes □ No Customer Leads: L^ Yes □ No
Number of Lamps: Total Wattage:. . Type of Lamp:.
Number of Ballast/Transformers: _ Input of Transformers:
Location of Switch
Type of Switch: f^VNN £^ -
Static: J^Yes □ No
Illuminated: $ Yes □ No
' If yes - External Internal ^
Dynamic Image Display: □ Yes ffl No
(An affidavit of compliance is required for all dynamic image display signs pursuant to Section 13-20-675(d)(2) of the Municipal Code of Chicago.)
Max Nits Max Foot Candles Message Time (Screen Hold): seconds
Sq Ft.
Self Dimming Capability: □ Yes □ No
What is the total of the sign face area devoted to dynamic image display?
Section 4 - Zoning Information^
Zoning District or Planned Development #: C-j " \
Is sign located in a special sign district? □ Yes L$ No
If yes: □ Michigan Avenue Corridor □ Oak Street Corridor □ State Street/Wabash Avenue Corridor
Total Street frontage of Zoning Lot: _ (Ft.)
Total Area of new sign: 17(^> (Sq Ft.) Gross Area of all proposed signs: IO (Sq Ft.)
(SqFt.)
_____
Total Area of all existing signs on Zoning Lot:
Picture or rendering must be attached depicting sign placement with before and after view.
Section 4 continues on next page
City of Chicago Sign Permit Application continued
Section 4 continued
(Ft.)
i_Z (Ft.)
Distance from outer edge of sign or structure to curb line:
_(Ft.) (Ft.)
Distance from inner edge of sign or sign structure to curb line: Distance from:
(Ft.)
Public Park 10 acres or more: Public Park 2 acres or more: _
A//A
(Ft.)
Expressway or Toll Road: A J IA
NfA
Lake Shore Drive:
(Ft.)
(Ft.)
(Ft.)
Michigan Avenue (Oak St. to Roosevelt Rd.):
Residential District: / 9^(0
Residential building in a D district:
Existing off-premise/advertising signs on same side of street? □ Yes $ No
In a B or C District: (Ft.)
In a D or M District: (Ft.)
Waterways: ft (A (Ft.)
Section 5 - Sign Permit History
Does the proposed sign, change, alter or replace an existing sign? □ Yes □ No
If yes, were permits issued for the sign being replaced, changed or altered? □ Yes □ No If yes, please list each permit number and date each permit was issued:
Permit Number: Permit Number: Permit Number: Permit Number:
Date issued: Date issued:. Date issued: Date issued:
Does the proposed sign change a static sign to a dynamic image display sign? □ Yes □ No
Does the proposed sign change or alter the square footage or the height of the sign or sign structure? □ Yes □ No
Does the proposed sign change an on-premise sign to an off-premise/advertising sign? □ Yes □ No
Section 6 - Attestation and Signatures
We, the undersigned, under penalty of perjury, do hereby affirm and attest that the above information is true, complete, and correct and acknowledge that incorrect information is grounds to revoke or rescind a permit.
Date
Date
Date
Owner of Real Property: _
Lessee of Real Property:
Expediter:
Date
Supervising Electrician: *AJLo>*4£- ^L^*J^g^-^l
Sign Erector:
Picture or rendering must be attached depicting sign placement with before and after view.
City of Chicago Sign Permit Application continued
For Office Use
ZONING
PUBLIC WAY
Sign Review Fee:
Zoning Review Fee: $ Total Fee: $.
Amount Paid: $ Balance Due: $_
PERMIT IS VALID FOR A PERIOD OF FIVE YEARS AFTER ISSUANCE. IT IS SOLELY THE RESPONSIBILITY OF THE OWNER OR LESSEE TO FILE FOR RENEWAL
* Once zoning fee is paid, this application is valid for a period of up to six months from payment date. Applies to sign permits applied for on or after April 2,2014.
City of Chicago Mayor Rahm Emanuel
Department of Buildings Felicia Davis, Commissioner
c E
Z3
§
T r- cn o co co ro
a t- _ . <i
> to » 1
_8
CO CO
co
1 § E «
_ "8 £
< _ " " ii s
is;
X ? u.
CO
o o
v■
CO CM
7-@
ill
" u o
*
o 8
Z C
Q Q.
O _ _
91 1 u
c o o
D. JO
g uj
(0 3
_ ca.
E
O
g o
CM
CQ «* co
CO CD CN
II
x _
II s (/)
to 5 -o
"8 11
o o $
c o
3 ca £
in
o
E a E
s
CO
E n
I
o
o5 1 O £
B
CO
O
s
10
t
IQ Q O
*"
5 S 55 S 58 5 2
CN CD CO
in a a co
ID
bode
3?? !_SjS3«58
to
SNN«SrPIOt8"2
Eianniaioi-ont
ss i 8
CO* CO CO*
^oSSSSSg S 8 8 8 S S ®
SSg
Is & ii
ra "P. cn
S S S «
<6
. ^ jq
CO t- ID J N W r °
5?S8. «i 3 §
^ O O O Q
o © S 8 8 £ o © b © c 3
CD *r d
8"
8 3 8
odd
i
^gssggsg
o o e
8 8
o o
oddddcie
3 a
_ o o o £999 o o o
a
5
o to
I
a 5
a
CO
CO OB
CO V)
to in x
J- 58 CO CO CO CO I*.
1
§ 1ft
C? ot
a E
II
c at
2 -
a>
£ to co co co co o © o o o o o
5 o. i»: is: i>; ^
£
5
t
_ f*. CO CO l*» ~ CO _ CNj CM tO
t~- CO (X) CM CM
a
TJ
n a
S> a a in
■I ggoi
£ 1
5
t- IN CO ^ 10 CO t-
Its-
(0
o
o
Ul <0 UJ
z o
g
z o o
z
a
<
o
g
a o
_
_ Ul
UJ
CO
CO U
a
O
CO
o u
_ o
u.
CM UJ
9
a.
Ul UJ <0
o z
CD
2 UJ
_J «*>
§§ Uj Q
Q f*-
CD
Ul UJ
5
z _ ©
o 3
fe 3000 pal
rebar
use rebar to remove bolt breakout in tension use rebar to remove bolt breakout in shear
BOLT
BdtCratto A307
BertB 1.220 h
am 0.97 \m
Flits 58000 psl
EDGE OF CONCRETE Iff CUBE OR SPREAD I ■ 10.0) AT MIDDLE OF ANCHOR BOLT PATTERN
TocOm Depth = 7,00 ft
xcoorcSnalo yooorcBrattt Front taft 40000 -18000 Front RtgW 60 000 -IB 000 Back Left -60000 le.ooo
Back RJgH 60 000 18 000
EDOB OF CONCRETE IIF AUOER1. ENTER 0 IF FOUNDATION tS NOT AUGURED
Otamatar 2 500 ft
121.0 0.0 0.0
ANCHOR BQLT(PIATE DESIGN fENTER BOLTS FROM INSIDE OUT! u coonMnate y cooftfivHo # bolts
55
55
121.000 1214)00 247000
46,009 t-k 0000 ft* 1.139 ft-k 0.000 k 0.000 k 3 324 k 26.19 k 27.80
1.27 k 2900 27.02 fell
IM ksl
121.0 00
0.0
Fxctofd Lojrfl
78 8 fl-k 0.0 ft* 1.8(1* 0.0 k 0.0 k 5.3 k 41.899 k 2032 k
Ix
j
L£
Mi My Mt Vx
(use 0.0 kips urtess uplift)
Nua Vua
V» Vl T
V
IVO.-
ft
Iv
BOLT LAYOUT vntodtiMnt
42 In
hock 000 In
hookdaslgnZA In
CaM s.107 ki
Com*, S.107 In
CaM S.107 ki
CaaMk 5.107 In
S, 11.000 ki
8, 11.000 In
OK
112 OK 41898.76 fts
0.75 2032.49 lbs 0.7
86202.00 lbs 22578.66 lbs
Ane 466.845 Anco 121.000 AncMnco 3.66 SHEAR/TENSION INTERACTION Nua/DNu ♦ Vua/OVn < 1.2 Nua« O n« Vua-O yo
Nn ■
Vn«
56202.00 ka
TENSION ANCHOR 8TREMOTH
Ntu
EFFECTIVE EMBEDMENT DEPTH
hal 3.67 cn
CONCRETE BREAKOUT STRENGTH
Neon N/A SEE REBAR SHEET lbs
PULLOUT STRENGTH
Npn 61051 JO lbs
CONCRETE SIDE FACE BLOWOUT
Nsb 60323.99 lbs
SHEAR ANCHOR SHEAR
Vea 26976.98 fca
BREAKOUT SHEAR
Vet N/A SEE REBAR SHEET Q»
PRYOUT SHEAR
Vcp 22576 68 lbs
REBAR DESIGN
Fy 60000 psi
<t> 0.75
Bar Size |
db |
As |
CDNu |
#bars/ab |
Ld |
min c/c |
max dist to ab |
#3 |
0.375 |
0.110 |
4970.098 |
8.43 |
9.86 |
0.9375 |
21 |
#4 |
0.500 |
0.196 |
8835.729 |
4.74 |
13.15 |
1.25 |
21 |
#5 |
0.625 |
0.307 |
13805.83 |
3.03 |
16.43 |
1.5625 |
21 |
#6 |
0.750 |
0.442 |
19880.39 |
2.11 |
19.72 |
1.875 |
21 |
#7 |
0.875 |
0.601 |
27059.42 |
1.55 |
28.76 |
2.1875 |
21 |
#8 |
1.000 |
0.785 |
35342.92 |
1.19 |
32.86 |
2.5 |
21 |
#9 |
1.125 |
0.994 |
44730.88 |
0.94 |
36.97 |
2.8125 |
21 |
#10 |
1.250 |
1.227 |
55223.31 |
0.76 |
42.79 |
3.125 |
21 |
#11 |
1.375 |
1.485 |
66820.2 |
0.63 |
51.78 |
3.4375 |
21 |
#12 |
1.500 |
1.767 |
79521.56 |
0.53 |
61.62 |
3.75 |
21 |
#13 |
1.625 |
2.074 |
93327.39 |
0.45 |
72.32 |
4.0625 |
21 |
#14 |
1.750 |
2.405 |
108237.7 |
0.39 |
83.87 |
4.375 |
21 |
db = bar diameter
As = cross-sectional area of one bar
<t>Nu = tensile strength of one piece of rebar
#bars/ab = NuaAPNu
Ld = development length required for bar (anchor bolts must be embedded more than Ld) min c/c = minimum center to center spacing of vertical rebar
max dist to ab = maximum distance rebar can be from anchor bolts in order to neglect breakout In design
z ^
m o
o
> I
NON-SHRINK GROUT
TOP OF FOOTING CONCRETE
FOOTING LEVELING NUT
1 1/4"0 GALV ANCHOR BOLT -0" LONG W/7" THREAD & TOP
BASE PLATE
BOTTOM NUT
& 2" THREAD @ BOTTOM (3) NUTS & (2) WASHERS PER BOLT,
ANCHOR BOLT DETAIL
N.T.S.
NOTICE;
CORNERSTONE ENGINEERING, INC IS RESPONSIBLE FOR COLUMN AND FOOTING DESIGN ONLY. SIGN CABINET COMPONENTS AND ATTACHMENT ARE THE RESPONSIBILITY OF THE SIGN MANUFACTURER.
HSS 8 X 6 X 3/8 SUPPORT COLUMN (2)
1
6-6 3/4"
C.TO (fc * *!■ i i i 1 1 1 iTt^ -
1 1/4*0 ANCHOR BOLT / SEE DETAIL
**rr GROUND
I,
JO - J6 BAR | 9-0" LONG
#3 TIES i 12" C/C
2-6"
■V CONCRETE FOOTING (2)
2-6"
DIAM
DIAM
ELEVATION VIEW
1 1/4V ANCHOR BOLT SEE DETAIL
C_ SIGN FACE
10 - #6 BAR
#3 TIES i 12" C/C
9^0* LONG
6-6 3/4" £T0 <£
CONCRETE FOOTING (2)
FOUNDATION PLAN VIEW
V