Record #: O2015-6021   
Type: Ordinance Status: Passed
Intro date: 7/29/2015 Current Controlling Legislative Body: Committee on Transportation and Public Way
Final action: 9/24/2015
Title: Grant(s) of privilege in public way for Smashotels Chicago LLC - manholes
Sponsors: Reilly, Brendan
Topic: PUBLIC WAY USAGE - Grants of Privilege
Attachments: 1. O2015-6021.pdf

ORDINANCE

SMASHOTELS CHICAGO, LLC Acct. No. 395139-1 Permit No. 1119388

 

Be It Ordained by the City Council of the City of Chicago:

SECTION 1. Permission and authority are hereby given and granted to SMASHOTELS CHICAGO, LLC, upon the terms and subject to the conditions of this ordinance to construct, install, maintain and use one (1) Manhole(s) under the public right-of-way adjacent to its premises known as 228 E. Ontario St

Said Manhole(s) at E. Ontario Street measure(s):

One (1) at two (2) feet in diameter.

The location of said privilege shall be as shown on prints kept on file with the Department of Business Affairs and Consumer Protection and the Office of the City Clerk.

Said privilege shall be constructed in accordance with plans and specifications approved by the Department of Transportation (Office of Underground Coordination) and Department of Water Management.

This grant of privilege in the public way shall be subject to the provisions of Section 10-28-015 and all other required provisions of the Municipal Code of Chicago.

The grantee shall pay to the City of Chicago as compensation for the privilege #1119388 herein granted the sum of four hundred ($400.00) per annum in advance.

A 25% penalty will be added for payments received after due date.

Page 1

The permit holder agrees to hold the City of Chicago harmless for any damage, relocation or replacement costs associated with damage, relocation or removal of private property caused by the City performing work in the public way.

 

 

 

(P.4ge',;4   of 7)

 

CHICAGO STANDARD MANHOLE FRAME AND CLOSED LID

PRECAST CONCRETE ADJUSTING RINGS. (6" MIN 12" MAX)

'ARIES 2'-6" TO 4'-3" MAY BE REPLACED BY OPTIONAL PRECAST REINF CONC FLAT SLAB TOP.

MASTIC OR MORTAR JOINTS IN STORM MANHOLES RUBBER GASKET (O-RINGS) IN SANITARY MANHOLES & IN COMBINED SEWER AREAS

STEPS AT 16" O.C , TYPICAL (3" EMBEDMENT, MIN.)

PRECAST REINF CONC SECTIONS (ASTM C-478) 48" DIA (UP TO 18" DIA PIPE), T=4"

INSTALL RESILIENT CONNECTORS (ASTM C-923) IN SANITARY AND COMBINED SEWER AREA MANHOLES

SEWER PIPE TO BE CONSTRUCTED. (PIPE SIZE, MATERIAL, AND SLOPE PER DRAWINGS)

 

CLASS X CONCRETE BENCH (MAY BE PREFABRICATED)

PREFABRICATED CONC SLAB ON SAND CUSHION OR CAST - IN - PLACE, CLASS X CONCRETE WITHOUT SAND CUSHION.

-6" FINE AGGREGATE (FA1 OR FA2) CUSHION

 

Date 05/29/15

CSK-2

ra TERRA

I ™ B4GMEB3NGUD.

225 W Ohio Street, 4th Floor Chicago, Illinois 60654 (312)4674123 (312)467-0220(ax

MANHOLE DETAIL GRANT OF PRIVILEGE

228 E. ONTARIO ST CHICAGO, IL